All Products

Latest News

ELM DEALERS
contact us today to receive an invitation to Register your business for our new ELM DEALER PORTAL. Dedicated B2B e-com, and so much more!

Click to send us your request
ELM News
Troubleshooting Course a Big Success!

Click Here for Article

We are located in Mississauga at:
6580 Davand Drive #1

We're Expanding Our Bilingual Order Desk (again)...

Read More ...
ELM content separator
***ELM 2018-19 CATALOGUE***

The new Interactive 2018-19
ELM e-Catalogue is here!

With Dynamic Table of Contents and Active Internal Navigation features, searching for the right part has never been easier!

***Catalogue 2018-19 d’ELM***
Le nouveau Catalogue électronique Interactif 2018-19 d'ELM est ici!

Avec des aspects d'une Table de Matières Dynamique et Navigation Interne Active, la recherche pour l'exacte pièce n'a jamais été aussi facile!


Read More ...
***NEW***

Contact us for your 2018-19 ELM Catalogue HARDCOPY today!

Contactez nous pour votre catalogue version papier 2018-2019 d'ELM aujourd'hui!


Read More ...
ELM hot tub spa parts
Spa Troubleshooting - Hot Tub Repair
Spa repair education, training videos, problem solving and hot tub maintenance

Read More ...
 
ELM Sales & Equipment Inc
6580 Davand Drive Unit 1
Mississauga, ON L5T 2M3 Canada
TOLL FREE: 888-502-6960
PH: 905-670-5387
FAX: 905-670-5389
info@elmsalesandequipment.com

Dealer Specials

Name :
Email :

Frequently Asked Questions.

Q-1: Why does my GFCI (ground fault circuit interrupter)trip when the spa is turned on?

Q-2: Why does my ground fault interrupter trip when my heater turns on?

Q-3: Why does my hot tub not heat after I turn on the heater?

Q-4: My pump is running but there is no flow - why?

Q-5: Why does my hot tub run only for several minutes and then trip the breaker?

Q-6: Why is there a temperature fluctuation in my hot tub that has a digital control?



Q-1: Why does my GFCI (ground fault circuit interrupter)trip when the spa is turned on?

A: The GFCI (ground fault circuit interrupter) or RCD may be wired wrong. Electricians are even confused about this sometimes. Be sure that the neutral wire is installed correctly. Some GFCI's require the neutral to be attached directly to the neutral bar where others run through the GFCI itself.


Q-2: Why does my ground fault interrupter trip when my heater turns on?

A: This would indicate that there is an electrical current leak at the heater element and it should be replaced. This should only be done by qualified personnel.


Q-3: Why does my hot tub not heat after I turn on the heater?

A: The filter may be dirty: Make sure that the filter is clean to allow proper flow through the heater. If there is not enough flow, the pressure switch will shut the heater off to prevent it from overheating and possibly burning out the heating element.


Q-4: My pump is running but there is no flow - why?

A: There may be an air lock in the pump: Try running the pump on high speed momentarily, if this does not work, the union fitting at the pump output will have to be opened slightly to allow air to purge. Your hot tub may have separate purge instructions for this. Make sure that there is enough water in the hot tub. It should not be sucking any air through the skimmer.


Q-5: Why does my hot tub run only for several minutes and then trip the breaker?

A: The wire gauge may be too small or the breaker may be too small: Check that the wiring and the breakers are sized properly and have been tightly connected. Loose connections will also cause a circuit overheat and trip the breaker.


Q-6: Why is there a temperature fluctuation in my hot tub that has a digital control?

A: The temperature sensor may be located in the wrong place or not insulated properly. It should be located in a sensor well that will provide exposure to the tub temperature and not be influenced by the outdoor ambient